@@ -0,0 +1,410 @@
|
||||
NEC <20>PD765 - Floppy Disk Controller - 8272A
|
||||
|
||||
PS/2 FDC Diskette Status Register A at 3F0h
|
||||
|
||||
<09>7<EFBFBD>6<EFBFBD>5<EFBFBD>4<EFBFBD>3<EFBFBD>2<EFBFBD>1<EFBFBD>0<EFBFBD> 3F0h PS/2 Disk Status Register A (read-only)
|
||||
<20> <20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD> direction
|
||||
<20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD> write protect
|
||||
<20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> index
|
||||
<20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> head 1 select
|
||||
<20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> track 0
|
||||
<20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> step
|
||||
<20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> second drive installed
|
||||
<20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> interrupt pending
|
||||
|
||||
PS/2 FDC Diskette Status Register B at 3F1h
|
||||
|
||||
<09>7<EFBFBD>6<EFBFBD>5<EFBFBD>4<EFBFBD>3<EFBFBD>2<EFBFBD>1<EFBFBD>0<EFBFBD> 3F1h PS/2 Disk Status Register B (read-only)
|
||||
<20> <20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD> motor enable 0
|
||||
<20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD> motor enable 1
|
||||
<20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD> write enable
|
||||
<20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD> read data (toggles w/positive transition in -RD DATA)
|
||||
<20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD> write data (toggles w/positive transition in WR DATA)
|
||||
<20> <20> <20><><EFBFBD><EFBFBD><EFBFBD> drive select
|
||||
<20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> reserved
|
||||
|
||||
FDC Digital Output Register at 3F2h (all systems)
|
||||
|
||||
<09>7<EFBFBD>6<EFBFBD>5<EFBFBD>4<EFBFBD>3<EFBFBD>2<EFBFBD>1<EFBFBD>0<EFBFBD> port 3F2h (write only)
|
||||
<20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> floppy drive select (0=A, 1=B, 2=floppy C, ...)
|
||||
<20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> 1 = FDC enable, 0 = hold FDC at reset
|
||||
<20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> 1 = DMA & I/O interface enabled (reserved PS/2)
|
||||
<20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> 1 = turn floppy drive A motor on
|
||||
<20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> 1 = turn floppy drive B motor on
|
||||
<20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> 1 = turn floppy drive C motor on; (reserved PS/2)
|
||||
<20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> 1 = turn floppy drive D motor on; (reserved PS/2)
|
||||
|
||||
- used to control drive motors, drive selection, and feature enable
|
||||
- PS/2 only uses bit 0 for floppy drive select; bit 1 is reserved
|
||||
- PS/2 only uses bits 5 & 4 for motor enable; bits 7&6 are reserved
|
||||
- all DOR bits are cleared during controller reset
|
||||
|
||||
FDC Main Status Register at 3F4h (all systems)
|
||||
|
||||
<09>7<EFBFBD>6<EFBFBD>5<EFBFBD>4<EFBFBD>3<EFBFBD>2<EFBFBD>1<EFBFBD>0<EFBFBD> port 3F4h (read only)
|
||||
<20> <20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD> floppy drive 0 in seek mode/busy
|
||||
<20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD> floppy drive 1 in seek mode/busy
|
||||
<20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> floppy drive 2 in seek mode/busy (reserved PS/2)
|
||||
<20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> floppy drive 3 in seek mode/busy (reserved PS/2)
|
||||
<20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> FDC read or write command in progress
|
||||
<20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> FDC is in non-DMA mode
|
||||
<20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> I/O direction; 1 = FDC to CPU; 0 = CPU to FDC
|
||||
<20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> data reg ready for I/O to/from CPU (request for master)
|
||||
|
||||
FDC Command Status Register 0 at 3F5h (all systems)
|
||||
|
||||
<09>7<EFBFBD>6<EFBFBD>5<EFBFBD>4<EFBFBD>3<EFBFBD>2<EFBFBD>1<EFBFBD>0<EFBFBD> Command Status Register 0 at port 3F5h
|
||||
<20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> unit selected at interrupt (0=A, 1=B, 2=...)
|
||||
<20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> head number at interrupt (head 0 or 1)
|
||||
<20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> not ready on read/write or SS access to head 1
|
||||
<20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> equipment check (see note)
|
||||
<20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> set to 1 when FDD completes a seek command
|
||||
<20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> last command status (see below)
|
||||
|
||||
Bits
|
||||
76 Last Command Status
|
||||
00 command terminated successfully
|
||||
01 command execution started but terminated abnormally
|
||||
10 invalid command issued
|
||||
11 command terminated abnormally due to a change in state of
|
||||
the Ready Signal from the FDC (reserved on PS/2)
|
||||
|
||||
- equipment check can occur if FDD signals a fault or track zero is
|
||||
not found after 77 steps on a recalibrate command
|
||||
- PS/2 only uses bits 1-0 for drive (values are 01b and 10b)
|
||||
|
||||
FDC Command Status Register 1 at 3F5h (all systems)
|
||||
|
||||
<09>7<EFBFBD>6<EFBFBD>5<EFBFBD>4<EFBFBD>3<EFBFBD>2<EFBFBD>1<EFBFBD>0<EFBFBD> Command Status Register 1 at port 3F5h
|
||||
<20> <20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD> FDC cannot find ID address mark (see reg 2)
|
||||
<20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD> write protect detected during write
|
||||
<20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> FDC cannot find sector ID
|
||||
<20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> unused (always zero)
|
||||
<20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> over-run; FDC not serviced in reasonable time
|
||||
<20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> data error (CRC) in ID field or data field
|
||||
<20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> unused (always zero)
|
||||
<20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> end of cylinder; sector# greater than sectors/track
|
||||
|
||||
- bit 0 of Status Register 1 and bit 4 of Status Register 2 are
|
||||
related and mimic each other
|
||||
|
||||
FDC Command Status Register 2 at 3F5h (all systems)
|
||||
|
||||
<09>7<EFBFBD>6<EFBFBD>5<EFBFBD>4<EFBFBD>3<EFBFBD>2<EFBFBD>1<EFBFBD>0<EFBFBD> Command Status Register 2 at port 3F5h
|
||||
<20> <20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD> missing address mark in data field
|
||||
<20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD> bad cylinder, ID not found and Cyl Id=FFh
|
||||
<20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> scan command failed, sector not found in cylinder
|
||||
<20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> scan command equal condition satisfied
|
||||
<20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> wrong cylinder detected
|
||||
<20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> CRC error detected in sector data
|
||||
<20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> sector with deleted data address mark detected
|
||||
<20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> unused (always zero)
|
||||
|
||||
- bit 0 of Status Register 1 and bit 4 of Status Register 2 are
|
||||
related and mimic each other
|
||||
|
||||
FDC Command Status Register 3 at 3F5h (FDD status, all systems)
|
||||
|
||||
<09>7<EFBFBD>6<EFBFBD>5<EFBFBD>4<EFBFBD>3<EFBFBD>2<EFBFBD>1<EFBFBD>0<EFBFBD> Floppy Disk Drive Status at port 3F5h
|
||||
<20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> FDD unit selected status (0=A, 1=B, 2=...)
|
||||
<20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> FDD side head select status (0=head 0, 1=head 1)
|
||||
<20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> FDD two sided status signal
|
||||
<20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> FDD track zero status signal
|
||||
<20> <20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> FDD ready status signal
|
||||
<20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> FDD write protect status signal
|
||||
<20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> FDD fault status signal
|
||||
|
||||
PS/2 FDC Digital Input Register at 3F7h
|
||||
|
||||
<09>7<EFBFBD>6<EFBFBD>5<EFBFBD>4<EFBFBD>3<EFBFBD>2<EFBFBD>1<EFBFBD>0<EFBFBD> 3F7h PS/2 Digital Input Register (read only)
|
||||
<20> <20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD> high density select
|
||||
<20> <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> reserved
|
||||
<20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> diskette change
|
||||
|
||||
PS/2 FDC Configuration Control Register at 3F7h
|
||||
|
||||
<09>7<EFBFBD>6<EFBFBD>5<EFBFBD>4<EFBFBD>3<EFBFBD>2<EFBFBD>1<EFBFBD>0<EFBFBD> 3F7h PS/2 Config. Control Register (write only)
|
||||
<20> <20> <20> <20> <20> <20> <20><><EFBFBD><EFBFBD><EFBFBD> DRC1, DRC0 (see below)
|
||||
<20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD><EFBFBD> reserved
|
||||
|
||||
DRC1 DRC0
|
||||
0 0 500000 bit per second mode
|
||||
0 1 reserved
|
||||
1 0 250000 bit per second mode
|
||||
1 1 reserved
|
||||
|
||||
|
||||
- Digital Input Register is used to sense the state of the
|
||||
(-diskette change) and the (-high density select) signals
|
||||
- Configuration Control Register is used to set the transfer rate
|
||||
|
||||
|
||||
FDC Programming Considerations
|
||||
|
||||
Three phases of command execution:
|
||||
|
||||
1. Command phase; commands are sent from the CPU to the FDC via
|
||||
port 3F5h; bit 6 of the Status Register at 3F4h must be zero
|
||||
2. Execution phase; FDC executes instruction & generates INT 6
|
||||
3. Result phase; status and other information is available to CPU;
|
||||
INT 6 sets bit 7 of BIOS Data Area location 40:3E which can
|
||||
be polled for completion status
|
||||
|
||||
|
||||
Example of a read operation:
|
||||
|
||||
1. turn disk motor on and set delay time for drive spin up
|
||||
2. perform seek operation; wait for disk interrupt
|
||||
3. prepare DMA chip to move data to memory
|
||||
4. send read command and wait for transfer complete interrupt
|
||||
5. read status information
|
||||
6. turn disk motor off
|
||||
|
||||
|
||||
Floppy Diskette Controller Operations (15 commands)
|
||||
|
||||
Read Data D7 D6 D5 D4 D3 D2 D1 D0
|
||||
|
||||
command byte 0: MT MF SK 0 0 1 1 0
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
command byte 2: cylinder number
|
||||
command byte 3: head number
|
||||
command byte 4: sector number
|
||||
command byte 5: bytes per sector
|
||||
command byte 6: end of track (last sector in track)
|
||||
command byte 7: gap 3 length
|
||||
command byte 8: data length (if cmd byte 5==0)
|
||||
result byte 0: status register 0
|
||||
result byte 1: status register 1
|
||||
result byte 2: status register 2
|
||||
result byte 3: cylinder number
|
||||
result byte 4: head number
|
||||
result byte 5: sector number
|
||||
result byte 6: bytes per sector
|
||||
|
||||
Read Deleted Data D7 D6 D5 D4 D3 D2 D1 D0
|
||||
|
||||
command byte 0: MT MF SK 0 1 1 0 0
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
command byte 2: cylinder number
|
||||
command byte 3: head number
|
||||
command byte 4: sector number
|
||||
command byte 5: bytes per sector
|
||||
command byte 6: end of track (last sector in track)
|
||||
command byte 7: gap 3 length
|
||||
command byte 8: data length (if cmd byte 5==0)
|
||||
result byte 0: status register 0
|
||||
result byte 1: status register 1
|
||||
result byte 2: status register 2
|
||||
result byte 3: cylinder number
|
||||
result byte 4: head number
|
||||
result byte 5: sector number
|
||||
result byte 6: bytes per sector
|
||||
|
||||
Write Data D7 D6 D5 D4 D3 D2 D1 D0
|
||||
|
||||
command byte 0: MT MF 0 0 0 1 0 1
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
command byte 2: cylinder number
|
||||
command byte 3: head number
|
||||
command byte 4: sector number
|
||||
command byte 5: bytes per sector
|
||||
command byte 6: end of track (last sector in track)
|
||||
command byte 7: gap 3 length
|
||||
command byte 8: data length (if cmd byte 5==0)
|
||||
result byte 0: status register 0
|
||||
result byte 1: status register 1
|
||||
result byte 2: status register 2
|
||||
result byte 3: cylinder number
|
||||
result byte 4: head number
|
||||
result byte 5: sector number
|
||||
result byte 6: bytes per sector
|
||||
|
||||
Write Deleted Data D7 D6 D5 D4 D3 D2 D1 D0
|
||||
|
||||
command byte 0: MT MF 0 0 1 0 0 1
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
command byte 2: cylinder number
|
||||
command byte 3: head number
|
||||
command byte 4: sector number
|
||||
command byte 5: bytes per sector
|
||||
command byte 6: end of track (last sector in track)
|
||||
command byte 7: gap 3 length
|
||||
command byte 8: data length (if cmd byte 5==0)
|
||||
result byte 0: status register 0
|
||||
result byte 1: status register 1
|
||||
result byte 2: status register 2
|
||||
result byte 3: cylinder number
|
||||
result byte 4: head number
|
||||
result byte 5: sector number
|
||||
result byte 6: bytes per sector
|
||||
|
||||
Read a Track D7 D6 D5 D4 D3 D2 D1 D0
|
||||
(Diagnostic)
|
||||
command byte 0: 0 MF SK 0 0 0 1 0
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
command byte 2: cylinder number
|
||||
command byte 3: head number
|
||||
command byte 4: sector number
|
||||
command byte 5: bytes per sector
|
||||
command byte 6: end of track (last sector in track)
|
||||
command byte 7: gap 3 length
|
||||
command byte 8: data length (if cmd byte 5==0)
|
||||
result byte 0: status register 0
|
||||
result byte 1: status register 1
|
||||
result byte 2: status register 2
|
||||
result byte 3: cylinder number
|
||||
result byte 4: head number
|
||||
result byte 5: sector number
|
||||
result byte 6: bytes per sector
|
||||
|
||||
Read ID D7 D6 D5 D4 D3 D2 D1 D0
|
||||
|
||||
command byte 0: 0 MF 0 0 1 0 1 0
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
result byte 0: status register 0
|
||||
result byte 1: status register 1
|
||||
result byte 2: status register 2
|
||||
result byte 3: cylinder number
|
||||
result byte 4: head number
|
||||
result byte 5: sector number
|
||||
result byte 6: bytes per sector
|
||||
|
||||
Format a Track D7 D6 D5 D4 D3 D2 D1 D0
|
||||
(Write Sector IDs)
|
||||
command byte 0: 0 MF 0 0 1 1 0 1
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
command byte 2: bytes per sector
|
||||
command byte 3: sectors per track
|
||||
command byte 4: gap 3 length
|
||||
command byte 5: filler pattern to write in each byte
|
||||
result byte 0: status register 0
|
||||
result byte 1: status register 1
|
||||
result byte 2: status register 2
|
||||
result byte 3: cylinder number
|
||||
result byte 4: head number
|
||||
result byte 5: sector number
|
||||
result byte 6: bytes per sector
|
||||
|
||||
Scan Equal D7 D6 D5 D4 D3 D2 D1 D0
|
||||
|
||||
command byte 0: MT MF SK 1 0 0 0 1
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
command byte 2: cylinder number
|
||||
command byte 3: head number
|
||||
command byte 4: sector number
|
||||
command byte 5: bytes per sector
|
||||
command byte 6: end of track (last sector in track)
|
||||
command byte 7: gap 3 length
|
||||
command byte 8: scan test (1=scan contiguous, 2=scan alternate)
|
||||
result byte 0: status register 0
|
||||
result byte 1: status register 1
|
||||
result byte 2: status register 2
|
||||
result byte 3: cylinder number
|
||||
result byte 4: head number
|
||||
result byte 5: sector number
|
||||
result byte 6: bytes per sector
|
||||
|
||||
Scan Low or Equal D7 D6 D5 D4 D3 D2 D1 D0
|
||||
|
||||
command byte 0: MT MF SK 1 1 0 0 1
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
command byte 2: cylinder number
|
||||
command byte 3: head number
|
||||
command byte 4: sector number
|
||||
command byte 5: bytes per sector
|
||||
command byte 6: end of track (last sector in track)
|
||||
command byte 7: gap 3 length
|
||||
command byte 8: scan test (1=scan contiguous, 2=scan alternate)
|
||||
result byte 0: status register 0
|
||||
result byte 1: status register 1
|
||||
result byte 2: status register 2
|
||||
result byte 3: cylinder number
|
||||
result byte 4: head number
|
||||
result byte 5: sector number
|
||||
result byte 6: bytes per sector
|
||||
|
||||
Scan High or Equal D7 D6 D5 D4 D3 D2 D1 D0
|
||||
|
||||
command byte 0: MT MF SK 1 1 1 0 1
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
command byte 2: cylinder number
|
||||
command byte 3: head number
|
||||
command byte 4: sector number
|
||||
command byte 5: bytes per sector
|
||||
command byte 6: end of track (last sector in track)
|
||||
command byte 7: gap 3 length
|
||||
command byte 8: scan test (1=scan contiguous, 2=scan alternate)
|
||||
result byte 0: status register 0
|
||||
result byte 1: status register 1
|
||||
result byte 2: status register 2
|
||||
result byte 3: cylinder number
|
||||
result byte 4: head number
|
||||
result byte 5: sector number
|
||||
result byte 6: bytes per sector
|
||||
|
||||
Recalibrate D7 D6 D5 D4 D3 D2 D1 D0
|
||||
|
||||
command byte 0: 0 0 0 0 0 1 1 1
|
||||
command byte 1: ? ? ? ? ? 0 US1 US0
|
||||
returns nothing
|
||||
|
||||
Sense Interrupt D7 D6 D5 D4 D3 D2 D1 D0
|
||||
Status
|
||||
command byte 0: 0 0 0 0 1 0 0 0
|
||||
result byte 0: status register 0
|
||||
result byte 1: present cylinder number
|
||||
|
||||
Specify Step & D7 D6 D5 D4 D3 D2 D1 D0
|
||||
Head Load
|
||||
command byte 0: 0 0 0 0 0 0 1 1
|
||||
command byte 1: step rate time <20> head unload time
|
||||
command byte 2: <20><><EFBFBD><EFBFBD><EFBFBD><EFBFBD>head load time<6D><65><EFBFBD><EFBFBD><EFBFBD><EFBFBD> ND
|
||||
returns nothing
|
||||
|
||||
Sense Drive D7 D6 D5 D4 D3 D2 D1 D0
|
||||
Status
|
||||
command byte 0: 0 0 0 0 0 1 0 0
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
result byte 0: status register 3
|
||||
|
||||
Seek D7 D6 D5 D4 D3 D2 D1 D0
|
||||
|
||||
command byte 0: 0 0 0 0 1 1 1 1
|
||||
command byte 1: ? ? ? ? ? HD US1 US0
|
||||
command byte 2: new cylinder number
|
||||
returns nothing
|
||||
|
||||
<20>PD765 Version D7 D6 D5 D4 D3 D2 D1 D0
|
||||
|
||||
command byte 0: ? ? ? 1 0 0 0 0
|
||||
result byte 0: status register 0
|
||||
90h = <20>PD765B; 80h = <20>PD765A or <20>PD765A-2
|
||||
|
||||
Invalid Command
|
||||
|
||||
result byte 0: status register 0 (value of 80h)
|
||||
|
||||
|
||||
Key to Abbreviations
|
||||
HD = Head Number Selected SK = SKip Deleted-data address mark
|
||||
MT = Multi-Track US0 = drive select bit 0
|
||||
MF = MFM mode US1 = drive select bit 1
|
||||
ND = Non-DMA mode
|
||||
|
||||
Head Load Time = 2 to 254ms in 2ms increments
|
||||
Head Unload Time = 16 to 240ms in 16ms increments
|
||||
Step Rate Time = 1 to 16ms in 1ms increments
|
||||
|
||||
|
||||
- PS/2 systems use the 8272A diskette controller which is software
|
||||
and port compatible with the NEC <20>PD765
|
||||
- accessed through ports 3F0h-3F7h; NEC <20>PD765 is accessed through
|
||||
ports 3F2h, 3F4h and 3F5h; the 8272A uses ports 3F0h, 3F1h,
|
||||
3F2h, 3F4h, 3F5h and 3F7h
|
||||
- data, command and status registers are all accessed through
|
||||
port 3F5h a register stack with one address presented to the bus
|
||||
- bit 7 of BIOS Data Area byte 40:3E can be polled to determine
|
||||
if a disk operation has completed; this bit is set by the
|
||||
interrupt handler when the operation has completed; it should
|
||||
be reset before continuing on with the next FDC operation
|
||||